av不卡在线一区二区三区,日本.欧美一区二区三区,亚洲激情黄色大片免费看,天堂在男人的双股之间

北京迪索儀器有限公司

當前位置:北京迪索儀器有限公司>>牛奶乳品分析儀>> 化學分析儀

化學分析儀

參  考  價面議
具體成交價以合同協(xié)議為準

產(chǎn)品型號

品       牌

廠商性質(zhì)其他

所  在  地

聯(lián)系方式:伍 先生查看聯(lián)系方式

更新時間:2024-07-29 14:06:43瀏覽次數(shù):202次

聯(lián)系我時,請告知來自 食品機械設(shè)備網(wǎng)
同類優(yōu)質(zhì)產(chǎn)品更多>
簡單介紹:1)可作免疫化學測定,配其他配件可測Na+,K+,Cl-,Li+等

化學分析儀

簡單介紹:

1)可作免疫化學測定,配其他配件可測Na+, K+, Cl-, Li+等元素;2)每天可處理300個樣品;

features

processing speeds up to 300 tests per hour

integrated reporting with full demographics

integrated wand bar-code scheduling and patient identification.

24-hour, 7 day per week standby electrolyte capability

automatic daily maintenance

system principle

random access, bench-top open system with 24 wavelengths available for applications. incorporates a

concave holographic grating/diode array spectrophotometer with a spectral

response from 340-740 nm. wavelengths of 340, 380, 405, 440, 465, 475, 490, 500, 512, 525,

540, 550, 560, 575, 585, 600, 610, 630, 640, 650, 675, 685, 700, 740 nm

are standard. control of sample and reagent handing, assay and data processing

is fully automatic through an ibm compatible 486 computer with keyboard and

fourteen inch color display. tests are processed at a rate of over 140 tests

per hour with workload throughput rate of about 130 tests using synermed reagents

and applications. the system is open for the addition of tests which may be added

through parameter settings entered through the keyboard.

reagent storage

reagents for up to 24 methods can be stored "on-board". over 100 additional methods can be pre-programmed and se-lected through bar code or keyboard.

sample presentation

there are four options for sample presentation:

sample tray for 42 disposable cups

sample tray for 42 seventy-five mm primary collection tubes

sample tray for 72 micro cups

stat samples can be added at any time

patient identification and workload scheduling

pre-printed barcode labels for sample tubes may be used or ma be generated through

an optional printer using an optional utility installed on the system

duplicate barcode labels or sequential numbers may be used to label sample tube

and requsistion.each speciman may be identified by barcode wand reader or its

number may be entered through the keyboard

test se-lection by patient sample can be achieved by wand reading a barcoded

test se-lection sheet. profiles may be se-lected in the same way. alternatively, the keyboard can be used with a test se-lection utility.

fully documented final reports including test results, normal limits, patient

name, physician, and identification number are printed in a format which can be se-lected and modified by the user.

extensive archiving of results is provided using the system"s hard disk.

on-line quality control

graphing of results, trends, and levy-jennings plots using 60 day fifo (first in first out)method, are standard.

assoy modes

assay modes for end point, zero order kinetic, first order kinetic, and

ummunochemical reactions are provided. reagent volumes of as little as 180

µl and as high as 350 µl may be detected. sample volumes from 2-150 µl may be se-lected.

calibration

up to five calibrators may be used for immunochemical reactions. factor

colibration may also be used. calibrator values and lot numbers are stored

in system memory.

automatic pre-dilution for immunoassay

immunochemistry methods requiring pre-dilution of the sample are performed directly on serum by the automatic

performance of a pre-dilution. the pre-dilution can be set for each method in the test porometers menu for each

method. thus, each method can have a unique pre-dilution.

built-in diagnostics

the system monitors a variety of instruument operations and system performance

can be monitored through the keyboard.

reagent level sensing is automatic.

serum level sensing is automatic.

walk-away operation

the system has a cuvette capacity of 140 cuvettes which are loaded as 10

cuvette segments. this provides for unattended operation of more than one hour.

immunochemistry capability

immunoproteins, therapeutic drugs, drigs of abuse and hormones can be assayed

with the system.

curve-fitting math for up to five standards is integral.

automatic pre-dilution by method.

180 µl miniimum read volume provides economy for immunochemistry reagent use.

small volume reagent storage is provided.

disposable cuvette avoids troublesome and expensive cross contamiination and

consequent repeats or errors.

system integration

the addition of the pluslyte with autosampler enables processinf electrolytes

with integrated sample management and report generation for na+, k+, cl-, li+ and bicarbonate.

the analette offers value

highest testing rate per instrument cost.

flexibility - random, stat, batch, special chemistry, immunochemistry, routine assay and profile.

simplicity - computer familiarity is unnecessary. limited keyboard interaction is required.

economy - 180 µl minimum reagent volume.

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復(fù)您~
在線留言
欧美日韩综合在线一区| 五月天婷婷一区二区三区久久| 中国三级片在线视频| 日本av在线一区二区| 操老骚逼三级黄视频| 久久久国产了楼凤| 亚洲精品成a人在线观看| 男男大鸡巴操小屁眼视频| 人妻少妇精品视频12p| 欧美一级淫片免费播放口| 亚洲欧美一区二区爽爽爽| 人妻熟女av一区二区三区| 中文字幕精品字幕一区二区三区| 中日韩中文字幕无码一本| 久久精品国产亚洲高清| 日本精品久久不卡一区二区| 美女亚洲福利视频| 少妇毛片一区二区三区免费视频| 亚洲乱熟女一区二区三区| 欧美国产日韩a欧美在线| 韩国精品视频一区二区在线观看| 大鸡巴操逼视频免费| 久久一区二区三区精华液介绍| 男的日女生批网页| 夜色成人免费观看| 少妇被黑人入侵在线观看| 国产高清一区二区三区四区色| 欧美日韩久久久一区二区三区| 伊人久久久久久久久香港| 女教师色色天天免费播放| 日本十八禁大骚逼| 亚洲欧洲精品无码久久久| 国产伦精品一区二区三区福利| 欧美精品一区二区三区四区五区| 爱爱视频小抽插动漫| 女生小穴色色视频| 欧美在线A片一区二区三区| 中文字幕精品字幕一区二区三区| 另类 专区 综合 中文| 欧美一区二区高清视频在线观看| 蜜桃av噜噜一区二区三区免费|