| 6kV~35kV 中低壓銅芯及鋁芯交聯(lián)聚乙烯絕緣電力電纜(YJV電纜,YJV22電纜,YJLV電纜,YJLV22電纜) | XLPE Insulated Power Cable | 交聯(lián)聚乙烯絕緣電力電纜是采用化學(xué)方法或物理方法,使聚乙烯分子由線型分子結(jié)構(gòu)轉(zhuǎn)變?yōu)槿S網(wǎng)狀結(jié)構(gòu),由熱塑性的聚乙烯變成熱固性的交聯(lián)聚乙烯,從而提高了聚乙烯的耐老化性能、機(jī)械性能和耐環(huán)境能力,并保持了優(yōu)良的電氣性能。 | 交聯(lián)聚乙烯絕緣電力電纜導(dǎo)體的允許長期zui高溫為90攝氏度,較低絕緣電纜、聚氯乙烯絕緣電纜和聚乙烯絕緣電纜高,且具有重量輕、結(jié)構(gòu)簡單、使用方便、耐化學(xué)腐蝕和敷設(shè)不受落差限制等優(yōu)點(diǎn)。 | 26/35KV電力電纜,18/30KV交聯(lián)電纜,12/20KVYJV電纜,8.7/15KVYJV22電纜線,6/10KV鋁芯交聯(lián)電纜線,3.6/6KVYJLV單芯電纜 | 中低壓交聯(lián)電纜產(chǎn)品標(biāo)準(zhǔn) Standard | 本產(chǎn)品按GB12706《額定電壓35V及以下銅芯、鋁芯塑料絕緣電力電纜》標(biāo)準(zhǔn)生產(chǎn),同時(shí)還可根據(jù)用戶需要按電工委員會(huì)推薦標(biāo)準(zhǔn)IEC、英國標(biāo)準(zhǔn)、德國標(biāo)準(zhǔn)及美國標(biāo)準(zhǔn)生產(chǎn)。 | The product is manufactured according to the standard of《GB12706 or IEC、BS、DIN and ICEA upon request. | 適用范圍 Applications | 本產(chǎn)品適用于工頻額定電壓3.6/6kv~26/35kv輸配電線路作配送電能子用。 | The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv. | 使用特性 Operating characteristics | · 工頻額定電壓U0/U為3.6/6kv~26/35kv。 | Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv. | · 電纜導(dǎo)體的zui高允許工作溫度:90℃。 | Max.admissible operating temperature of the conductor:90℃. | · 短路時(shí)(zui長時(shí)間不超過5s)電纜導(dǎo)體的zui高溫度不超過2500C。 | Max. short-circurt temperature of conductor shall not exceed 2500C. | (5s maximum duration) | · 電纜敷設(shè)時(shí)環(huán)境溫度應(yīng)不低于00C。 | The ambient temperature under installation should not below 00C. | · 電纜彎曲半徑:三芯電纜不小于電纜外徑15倍;單芯電纜不小于電纜外徑20倍。 | The bending radius of a single-core cable should not less than 20 times of the cable diameter. | The bending radius of a single-core cable should not less than 15 times of the cable diameter. | 電纜額定電壓的選擇 Voltage designation | · 電纜的額定電壓應(yīng)適合于電纜系統(tǒng)的運(yùn)行狀況,用U0/U(Um)kv表示。 | U0-電纜設(shè)計(jì)用的導(dǎo)體對(duì)地或金屬屏蔽之間的額定工頻電壓; | U-電纜設(shè)計(jì)用的導(dǎo)體間的額定工頻電壓; | Um-設(shè)備可承受的“zui高系統(tǒng)電壓"的zui大值。 | The rated voltage of the cable for a given applixation shall be suitable for the operating conditions | in the system in which the cable is used,and is expressed in the form of U0/U(Um)kv | Where: | U0-The rated power-frequency voltage between conductors and earth metallic screen ,for which the cable designed; | U - The rated power-frequency voltage between conductos, for which the cable designed; | Um- The maximum value of the“highest system voltage"for which the equipment may beused. | · 三相系統(tǒng)用電纜的U0值推薦如下表: | The values of U0 recommened for cable to be used in three-phase systems are listed below: | | | U kvU m kvU 0 * kv | A 和 B 類系統(tǒng) System categories A and BC 類系統(tǒng) Systems categories C | 67.23.66 | 101268.7 | 1517.58.712 | 20241218 | 303618- | 3540.52126 | A類系統(tǒng)──該類系統(tǒng)任何一相導(dǎo)體與地和接地導(dǎo)體接觸時(shí),能在1min內(nèi)與系統(tǒng)分離 | B類系統(tǒng)──該類系統(tǒng)僅包括單相接地故障短時(shí)運(yùn)行的條件,接地故障時(shí)間應(yīng)不超過1h, 但在任何情況下,zui長不超過8h每年接地故障總持續(xù)時(shí)間不超過125h; | C類系統(tǒng)──不屬于A類、B類的系統(tǒng)。 | System category A──This category comprises those systems in which any phase conductor that comes in contact with earth or an earth conductor. is disconnected from the system within 1 min. | System category B ──This category comprises those system which,under faultconditions,are operated,are operated for ashorttimewith one phase earthed.This period should not exceed 1 h..Fora longer period, not exceeding 8h on any occasion, can be tolerated.The total duration of earth faults in any year should not exceed 125h. | System categeory C──This category comprises all systems which do not fall into A and B | 電纜的型號(hào)Type of cable | 型號(hào) Type名稱 Designation適用范圍 Application | YJV 銅芯交聯(lián)聚乙烯絕緣氯乙烯護(hù)套電力電纜 Copper conductor,XLPE insulated and PVC sheathed power cable 室內(nèi)、隧道及電纜溝等場所,不能承受機(jī)械外力。單芯電纜不允許敷設(shè)在磁性管道中。 For laying indoors 、 intunnel or cable trench,unable to bear external mechan-icalforces.Single-core cable in magnetic duct is not permissible | YJLY 鋁芯交聯(lián)聚乙烯絕緣乙烯護(hù)套電力電纜 Aluminium conductor, XLPE insulated and PVC sheathed power cable | YJY 銅芯交聯(lián)聚乙烯絕緣氯乙烯護(hù)套電力電纜 Copper conductor ,XLPE insulated and PEsheathed power cable | YJLY 鋁芯交聯(lián)聚乙烯絕緣氯乙烯護(hù)套電力電纜 Alumimium conductor ,XLPE insulated and PEsheathed power cable | YJV22 銅芯交聯(lián)聚乙烯絕緣鋼帶鎧裝聚氯乙烯護(hù)套電力電纜 Copper conductor ,XLPE insulated, steel tape armoured and PVC sheathed power cable 室內(nèi)、隧道、電纜溝內(nèi),或埋地敷設(shè)等,能承受一定機(jī)械外力,但不能承受大的拉力。 For laying indoors 、 in tunnel, cable trench, or direct in ground,able to bear external mechanicalforces, but unable to bear large pulling force 。 | YJLV22 鋁芯交聯(lián)聚乙烯絕緣鋼帶鎧裝聚氯乙烯護(hù)套電力電纜 Aluminium conductor ,XLPE insulated ,steel tape armoured and PVC sheathed power cable | YJV23 銅芯交聯(lián)聚乙烯絕緣鋼帶鎧裝聚氯乙烯護(hù)套電力電纜 Copper conductor ,XLPE insulated ,steel tape armoured and PVC sheathed power cable | YJLV23 鋁芯交聯(lián)聚乙烯絕緣鋼帶鎧裝聚氯乙烯護(hù)套電力電纜 Aluminium conductor ,XLPE insulated ,steel tape armoured and PVC sheathed power cable | YJV32 銅芯交聯(lián)聚乙烯絕緣細(xì)鋼絲鎧裝聚氯乙烯護(hù)套電力電纜 Copper conductor,XLPE insulated,steel wire armoured and PVC sheathed power cable 室內(nèi)、隧道、電纜溝、豎井或埋地敷設(shè)等,能承受機(jī)械外力和一定的拉力。 For laying indoors 、 in tunnel, cable french, well or direct in ground,able to bear external mechanical forces, and certain force 。 | YJLV32 鋁芯交聯(lián)聚乙烯絕緣細(xì)鋼絲鎧裝聚氯乙烯護(hù)套電力電纜 Aluminium conductor ,XLPE insulated, steel wire armoured and PVC sheathed power cable | YJV33 銅芯交聯(lián)聚乙烯絕緣細(xì)鋼絲鎧裝聚氯乙烯護(hù)套電力電纜 Copper conductor ,XLPE insulated ,steel wire armoured and PVC sheathed power cable | YJLV33 鋁芯交聯(lián)聚乙烯絕緣鋼帶鎧裝聚氯乙烯護(hù)套電力電纜 Aluminium conductor ,XLPE insulated ,steel wire armoured and PVC sheathed power cable | 生產(chǎn)范圍Production range of cable | 型號(hào) Type芯數(shù) Nomber of cores額定電壓 Rated Voltage kV | 3.6/66/6 6/108.7/10 8.7/1512/2018/20 18/3021/3526/35 | 導(dǎo)體標(biāo)稱截面 Nominal cross-section of conductlr mm2 | YJV | YJLV | YJY | YJLY125-80025-80025-80035-80050-63050-63050-630 | 325-63025-63025-50035-50050-40050-40050-400 | YJV22 | YJLV22 | YJY23 | YJLY23125-80025-80025-80035-80050-63050-63050-630 | 325-63025-63025-50035-50050-40050-40050-400 | YJV32 | YJLV32 | YJY33 | YJLY33125-80025-80025-80035-80050-63050-63050-630 | 325-63025-63025-40035-40050-24050-18550-150 | | |